Get Ready to Boost your Prepare for your DES-4122 Exam with 62 Questions [Q26-Q48]

Share

Get Ready to Boost your Prepare for your DES-4122 Exam with 62 Questions

Use Free DES-4122 Exam Questions that Stimulates Actual EXAM


EMC DES-4122 exam is intended for IT professionals who have experience in implementing and managing Dell EMC server solutions, including system administrators, implementation engineers, and technical support professionals. DES-4122 exam measures the candidates' proficiency in various areas of Dell EMC PowerEdge server solutions, including hardware installation, configuration, and maintenance, as well as software installation, configuration, and troubleshooting.


The DES-4122 exam is a specialist-level certification exam that requires candidates to have a good understanding of Dell EMC PowerEdge server solutions. Candidates are required to have a minimum of one year of experience in implementing and managing Dell EMC PowerEdge server solutions before taking the exam. DES-4122 exam consists of 60 multiple-choice questions and has a duration of 90 minutes. Candidates who pass the exam will receive the EMC Specialist - Implementation Engineer, PowerEdge certification, which is recognized globally and demonstrates their expertise in implementing Dell EMC PowerEdge server solutions.

 

NEW QUESTION # 26
Match each RAID level to its characteristic.

Answer:

Explanation:


NEW QUESTION # 27
Which type of access is known as Firmware RACADM on a Dell EMC PowerEdge server?

  • A. Accessing RACADM with OpenManage software
  • B. Accessing RACADM running the Dell Toolkit
  • C. Logging into iDRAC using SSH or Telnet
  • D. Logging into iDRAC through Boot Manager

Answer: C


NEW QUESTION # 28
Which processor configuration is used by the Dell EMC PowerEdge R740 server?

  • A. 2 socket AMD
  • B. 4 socket Intel
  • C. 2 socket Intel
  • D. 4 socket AMD

Answer: C


NEW QUESTION # 29
A system engineer has a 14G Dell EMC Poweredge server with an amber light blinking. The engineer must pull a SupportAssist collection before calling Dell Support to evaluate what the potential problem. Use the simulator to collect and view the SupportAssist collection.

  • A. A technician wants to
  • B. Send us your suggestion for this simulation task.

Answer: B


NEW QUESTION # 30
Dell EMC PowerEdge 14G servers support which technology?

  • A. Quicksync 1.0
  • B. AMD GuardMI
  • C. iDRAC8
  • D. Intel Boot Guard

Answer: B


NEW QUESTION # 31
What happened on April 30, 2019?


Note: It is necessary to dose (x) the simulator window before you can select a response to this question.

  • A. Option B
  • B. Option C
  • C. Option A
  • D. Option D

Answer: B


NEW QUESTION # 32
A technician needs to repurpose a Dell EMC PowerEdge server. The server has dual processors with 18 cores each The OS only "sees" 24 threads in total.
Which setting should the technician change in Processor Settings in the System BIOS?

  • A. HyperThreading
  • B. Virtualization Technology
  • C. System Profile
  • D. Number of Cores per Processor

Answer: C


NEW QUESTION # 33
What must be done before upgrading OMSA from the 32-bit to the 64-bit version?

  • A. Back up the configuration
  • B. Save the license file
  • C. Uninstall the earlier version
  • D. Disable UAC

Answer: B


NEW QUESTION # 34
What is a characteristic of SupportAssist Enterprise on Dell EMC PowerEdge 14G servers?

  • A. Used for customers that want monitoring of fewer than 1,000 server, storage, and networking devices
  • B. Proactive, predictive, and automated support technology to enable faster resolution and reporting
  • C. Includes onsite monitoring and automated collection of system state information
  • D. Dispatches technical support from Dell for all Dell servers, storage, and networking devices

Answer: C


NEW QUESTION # 35
Match each RAID level to its characteristic.

Answer:

Explanation:


NEW QUESTION # 36
What is a requirement to operate GPUs in a Dell EMC PowerEdge R740 server?

  • A. All GPU cards must be installed on the same riser card.
  • B. All GPU cards must be of the same type and model
  • C. All GPU cards must be of the same type but can be a different model
  • D. All GPU cards must be installed at the same time

Answer: D


NEW QUESTION # 37
A company that has very specific firmware requirements has acquired Dell EMC PowerEdge servers Any replaced parts of the type must match the original parts identically. The procedure must be as simple as possible with minimal risk.
What action should a technician take to help accomplish this goal?

  • A. Install and configure a repository manager
  • B. Configure servers to access the remote firmware repository
  • C. Enable the Match Firmware of Replaced Part setting in the system BIOS
  • D. Enable the Collect System Inventory On Restart (CSIOR) attribute

Answer: C


NEW QUESTION # 38
For security reasons, the Dell EMC PowerEdge server power button must be disabled. Use the System Setup Utility in the simulator to disable the power button. When you have finished using the simulator, click Next.

Answer:

Explanation:
Send us your suggestion for this simulation task.


NEW QUESTION # 39
A technician needs to update the IDRAC license on a Dell EMC PowerEdge R740 server from Express to Enterprise. The server has the following components:
* 2x CPUs
* 384 GB RAM
* 6x 1 TB drives
* 1x PSU
The server is connected to active AC, but it is powered down, and it needs to stay powered down No errors are presently displayed How can the technician upgrade the license?

  • A. The license cannot be upgraded because the user will not allow the server to be powered on
  • B. Connect to the iDRAC GUI and upgrade the .DRAC license while the server .s powered down
  • C. Power on the server, then connect to the iDRAC and upgrade iDRAC license before powering down the server
  • D. The license cannot be upgraded on a single PSU system

Answer: D


NEW QUESTION # 40
What is a characteristic of SupportAssist Enterprise on Dell EMC PowerEdge 14G servers?

  • A. Used for customers that want monitoring of fewer than 1,000 server, storage, and networking devices
  • B. Includes onsite monitoring and automated collection of system state information
  • C. Proactive, predictive, and automated support technology to enable faster resolution and reporting
  • D. Dispatches technical support from Dell for all Dell servers, storage, and networking devices

Answer: C


NEW QUESTION # 41
What is a key distinction between 1DRAC8 and 1DRAC9?

  • A. iDRAC8 default credentials are customer orderable
  • B. iDRAC9 offers HTML5 based GUI
  • C. iDRAC8 offers HTML5 based GUI
  • D. iDRAC9 default credentials are root/calvin orderable only

Answer: C


NEW QUESTION # 42
What is the correct order of steps taken during the BIOS/UEFI Recovery process?

Answer:

Explanation:


NEW QUESTION # 43
An engineer wants to fully leverage Microsoft Windows Server 2016 for TPM-based guarded host deployment of a 14G server Which BIOS settings need to be used for installing the Windows server?
A)

B)

C)

D)

  • A. Option B
  • B. Option C
  • C. Option A
  • D. Option D

Answer: B


NEW QUESTION # 44
You are Investigating a disk error on a Dell EMC PowerEdge server and discover a Hot Spare has not been assigned to the Virtual Disk Group. Use the simulator to assign the Global Hot Spare. When you have finished using the simulator, dick Next.

  • A. A technician wants to
  • B. Send us your suggestion for this simulation task.

Answer: B


NEW QUESTION # 45
Which mobile devices are supported by Quick Sync 2.0 in 14G PowerEdge servers?

  • A. Android devices only
  • B. iOS, Android, and Windows Phone devices
  • C. iOS devices only
  • D. iOS and Android devices only

Answer: D


NEW QUESTION # 46
For a temporary migration task the CPU core count on the Dell EMC PowerEdge R640 server needs to be reduced to 8 because the installed application will not work due to license restrictions. Use the simulator to apply the change so the application can be installed.
When you have finished using the simulator, click Next.

  • A. A technician wants to
  • B. Send us your suggestion for this simulation task.

Answer: B


NEW QUESTION # 47
For security reasons, the Dell EMC PowerEdge server power button must be disabled. Use the System Setup Utility in the simulator to disable the power button. When you have finished using the simulator, click Next.

  • A. A technician wants to
  • B. Send us your suggestion for this simulation task.

Answer: B


NEW QUESTION # 48
......

BEST Verified EMC DES-4122 Exam Questions (2024) : https://www.exam4pdf.com/DES-4122-dumps-torrent.html

Get 100% Real DES-4122 Free Online Practice Test: https://drive.google.com/open?id=1dqXZofVwZjlOd09FGW5o7BEo3XLWC3la